Power Entry Module
Power Entry Module EN60320 C8 + Switch
0721-S Series :
![]()
- Power Inlet
- 2.5A 250V AC Europe, 7A 125V AC North America
- over 100MΩ 500V DC
- 2,000V AC for One Minute
- +70℃
- Thermoplastic UL Flammability, 94V-0 & Copper Alloy
- Rocker Switch
- 3A 250V AC Europe, 6A 125V AC North America
- over 100MΩ 500V DC
- 1,000V AC for One Minute
- +85℃(Europe) / +125℃(North America)
- Thermoplastic UL Flammability, 94V-0 & Copper Alloy
0721-S Series :
![]()
- Power Inlet
- 2.5A 250V AC Europe, 7A 125V AC North America
- over 100MΩ 500V DC
- 2,000V AC for One Minute
- +70℃
- Thermoplastic UL Flammability, 94V-0 & Copper Alloy
- Rocker Switch
- 10A 250V AC
- over 100MΩ 500V DC
- 1,500V AC for One Minute
- +100℃
- Thermoplastic UL Flammability, 94V-0, 94V-2 & Copper Alloy
Power Entry Module EN60320 C6 + Switch
0724-S Series :
![]()
- Power Inlet
- 2.5A 250V AC Europe, 7A 125V AC North America
- over 100MΩ 500V DC
- 2,000V AC for One Minute
- +70℃
- Thermoplastic UL Flammability, 94V-0 & Copper Alloy
- Rocker Switch
- 3A 250V AC Europe, 6A 125V AC North America
- over 100MΩ 500V DC
- 1,000V AC for One Minute
- +85℃(Europe) / +125℃(North America)
- Thermoplastic UL Flammability, 94V-0 & Copper Alloy
0724-S Series :
![]()
- Power Inlet
- 2.5A 250V AC Europe, 7A 125V AC North America
- over 100MΩ 500V DC
- 2,000V AC for One Minute
- +70℃
- Thermoplastic UL Flammability, 94V-0 & Copper Alloy
- Rocker Switch
- 10A 250V AC
- over 100MΩ 500V DC
- 1,500V AC for One Minute
- +100℃
- Thermoplastic UL Flammability, 94V-2 & Copper Alloy
0724-S Series :
![]()
- Power Inlet
- 2.5A 250V AC Europe, 7A 125V AC North America
- over 100MΩ 500V DC
- 2,000V AC for One Minute
- +70℃
- Thermoplastic UL Flammability, 94V-0 & Copper Alloy
- Rocker Switch
- 6A 250V AC Europe, 12A 125V AC North America
- over 100MΩ 500V DC
- 1,500V AC for One Minute
- +85℃(Europe) / +125℃(North America)
- Thermoplastic UL Flammability, 94V-0 & Copper Alloy
0724-S Series :
![]()
- Power Inlet
- 2.5A 250V AC Europe, 7A 125V AC North America
- over 100MΩ 500V DC
- 2,000V AC for One Minute
- +70℃
- Thermoplastic UL Flammability, 94V-0 & Copper Alloy
- Rocker Switch
- 10A 250V AC
- over 100MΩ 500V DC
- 1,000V AC for One Minute
- +90℃(Europe) / +65℃(North America)
- Thermoplastic UL Flammability, 94V-2 & Copper Alloy
Power Entry Module EN60320 C14 + Switch
0711-S Series :
![]()
- Power Inlet
- 10A 250V AC Europe, 15A 125V AC North America
- over 100MΩ 500V DC
- 2,000V AC for One Minute
- +70℃
- Thermoplastic UL Flammability, 94V-0 & Copper Alloy
- Rocker Switch
- 6A 250V AC Europe, 12A 125V AC North America
- over 100MΩ 500V DC
- 1,500V AC for One Minute
- +85℃(Europe) / +125℃(North America)
- Thermoplastic UL Flammability, 94V-0 & Copper Alloy
0711-S Series :
![]()
- Power Inlet
- 10A 250V AC Europe, 15A 125V AC North America
- over 100MΩ 500V DC
- 2,000V AC for One Minute
- +70℃
- Thermoplastic UL Flammability, 94V-0 & Copper Alloy
- Rocker Switch
- 10A 250V AC
- over 100MΩ 500V DC
- 1,500V AC for One Minute
- +90℃(Europe) / +65℃(North America)
- Thermoplastic UL Flammability, 94V-2 & Copper Alloy
0711-1RS Series :
![]()
- Power Inlet
- 10A 250V AC
- over 100MΩ 500V DC
- 2,000V AC for One Minute
- +70℃
- Thermoplastic UL Flammability, 94V-0 & Copper Alloy
- Rocker Switch
- 10A 250V AC
- over 100MΩ 500V DC
- 1,000V AC for One Minute
- +100℃(SPST) / +105℃(DPST)
- Thermoplastic UL Flammability, 94V-2 & Copper Alloy
Power Entry Module EN60320 C14 + Sheet F
0712 Series :
![]()
- Power Inlet
- 10A 250V AC Europe, 15A 125V AC North America
- over 100MΩ 500V DC
- 2,000V AC for One Minute
- +70℃
- Thermoplastic UL Flammability, 94V-0 & Copper Alloy
- Power Outlet
- 10A 250V AC
- over 100MΩ 500V DC
- 1,000V AC for One Minute
- -25℃ ~ +70℃(North America)
- Thermoplastic UL Flammability, 94V-0 & Copper Alloy
Power Entry Module EN60320 C14 + Fuseholder
0717 / 0717-1 Series :
![]()
- Power Inlet
- 6.3A 250V AC Europe, 10A 125V AC North America
- over 100MΩ 500V DC
- 2,000V AC for One Minute
- +70℃
- Thermoplastic UL Flammability, 94V-0 & Copper Alloy
0717-2 Series :
![]()
- Power Inlet
- 10A 250V AC
- over 100MΩ 500V DC
- 2,000V AC for One Minute
- +70℃
- Thermoplastic UL Flammability, 94V-0 & Copper Alloy
Power Entry Module EN60320 C14 + Switch + Fuseholder
0717-1S Series :
![]()
- Power Inlet
- 6.3A 250V AC Europe, 10A 125V AC North America
- over 100MΩ 500V DC
- 2,000V AC for One Minute
- +70℃
- Thermoplastic UL Flammability, 94V-0 & Copper Alloy
- Rocker Switch
- 10A 250V AC
- over 100MΩ 500V DC
- 1,500V AC for One Minute
- +105℃
- Thermoplastic UL Flammability, 94V-2 & Copper Alloy
0717-2S Series :
![]()
- Power Inlet
- 10A 250V AC
- over 100MΩ 500V DC
- 2,000V AC for One Minute
- +70℃
- Thermoplastic UL Flammability, 94V-0 & Copper Alloy
- Rocker Switch
- 10A 250V AC
- over 100MΩ 500V DC
- 1,500V AC for One Minute
- +90℃(Europe) / +65℃(North America)
- Thermoplastic UL Flammability, 94V-2 & Copper Alloy
Power Entry Module EN60320 C20 + Switch
0722-S Series :
![]()
- Power Inlet
- 16A 250V AC Europe, 20A 250V AC North America
- over 100MΩ 500V DC
- 2,000V AC for One Minute
- +70℃
- Thermoplastic UL Flammability, 94V-0 & Copper Alloy
- Rocker Switch
- 10A 250V AC
- over 100MΩ 500V DC
- 1,500V AC for One Minute
- +125℃
- Thermoplastic UL Flammability, 94V-2 & Copper Alloy